Product Description
GASCO | 58L-252-10 | X02NI99CP584571 | Chlorine 10 PPM | balance Nitrogen | 58 Liter |connection C-10 | Certificate NIST | Made in the USA
The Calgaz X02NI99CP584571 (Calgaz Part # X02NI99CP584571 / Cross-Reference # 58L-252-10) is an industry-standard, NIST-traceable 10 PPM Chlorine (Cl2) with a Balance of Nitrogen (N2) specialty calibration gas mixture. Packaged in a lightweight, high-integrity 58-liter aluminum cylinder (Calgaz 6D), this standard is engineered for precision span checks, routine bump testing, and field calibration of fixed and portable toxic gas detection instruments.
Key Mixture Highlights
- Target Analyte: 10 PPM Chlorine (Cl2)
- Balance Component: High-Purity Nitrogen (N2)
- Traceability: Individually analyzed and certified against NIST-traceable reference standards. COA available via QR code on Cylinder Label
- Cross-Reference Part Number: 58L-252-10
- Cylinder Model: Calgaz 6D (58L Aluminum)
- Origin: Precision blended and certified in the USA
Technical Specifications
| Manufacturer | Calgaz |
|---|---|
| Part Numbers | X02NI99CP584571 | 58L-252-10 |
| Gas Chemistry | Chlorine (Cl2) 10 PPM / Balance Nitrogen (N2) |
| Cylinder Volume | 58 Liters (Calgaz 6D Cylinder) |
| Cylinder Construction | Seamless Aluminum (Essential for active/reactive gas stability) |
| Valve Connection | C-10 (5/8"-18 UNF Thread) |
| Cylinder Pressure | Approx. 500 psig (34.5 bar) |
| Analytical Accuracy | ±10% Analytical Tolerance |
| Warranty / Shelf Life | 12 Months (Reactive Gas Standard) |
| Country of Origin | Made in the USA |
Hardware & Compatibility Requirements
Because Chlorine is a highly corrosive and reactive halogen, this cylinder features a standard C-10 outlet (5/8"-18 UNF) and strictly requires stainless steel or passivated non-reactive regulators:
- Recommended Regulators: Calgaz 714 / 700-Series fixed-flow regulators (0.5 LPM or 1.0 LPM in Stainless Steel / Nickel-Plated Brass) or Calgaz DFR 2000 Series Demand Flow Regulators designed for reactive service.
- Tubing Compatibility: Use only non-absorptive PTFE (Teflon) or FEP tubing. Do not use Tygon, neoprene, or standard vinyl tubing, as reactive chlorine will readily adsorb onto interior walls, causing severe sensor calibration loss.
- Compatible Detectors: Suitable for multi-gas and single-gas toxic monitors from RAE Systems, Honeywell Analytics / BW Technologies, MSA Safety, Industrial Scientific, Dräger, and RKI Instruments configured with electrochemical chlorine sensors.